Clamp size Opening 1.2" (30mm) approx
Diode Test Test current of 0.3mA typical; Open
circuit voltage 1.5V DC typical.
Continuity Check Threshold <150; Test current
< 0.5mA
Low Battery Indication ” is displayed
Overrange Indication “OL” is displayed
Measurements Rate 2 per second, nominal
Input Impedance 10M (VDC and VAC)
Display 4000 counts LCD
AC Current 50-60Hz (AAC)
AC Voltage bandwidth 50-400Hz (VAC)
Operating Temperature 41 to 104
o
F (5 to 40
o
C)
Storage Temperature -4 to 140
o
F (-20 to 60
o
C)
Operating Humidity Max 80% up to 87°F (31°C) decreasing
linearly to 50% at 104°F(40°C)
Storage Humidity <80%
Operating Altitude 7000ft. (2000meters) maximum.
Over voltage Category III 600V
Battery Two AAA1.5V Battery
Auto OFF approx. 30 minutes
Dimensions/Weight 200x66x37mm/205g
Safety For indoor use and in accordance
with Overvoltage Category II,
Pollution Degree 2. Category II
includes local level, appliance,
portable equipment, etc., with
transient overvoltages less than
Overvoltage Cat. III